HAMSTAD Benchmark 2: Moisture Transport in a homogeneous wall
Application ID: 86381
This case shows how to simulate moisture transport in a homogeneous wall under isothermal conditions. With this assumption, an analytical solution can be calculated. The homogeneous layer is initialized in moisture balance. At the beginning of the simulation, the relative humidity of exterior and interior is shifted to lower values. The 1D model is the second benchmark test defined in HAMSTAD-WP2 Modeling for the validation of numerical simulations for coupled heat and moisture transport in building materials.
This model example illustrates applications of this type that would nominally be built using the following products:
however, additional products may be required to completely define and model it. Furthermore, this example may also be defined and modeled using components from the following product combinations:
- COMSOL Multiphysics® and
- either the Heat Transfer Module, or Porous Media Flow Module
The combination of COMSOL® products required to model your application depends on several factors and may include boundary conditions, material properties, physics interfaces, and part libraries. Particular functionality may be common to several products. To determine the right combination of products for your modeling needs, review the Tabella delle Funzionalità and make use of a free evaluation license. The COMSOL Sales and Support teams are available for answering any questions you may have regarding this.